Liquid temperature indicator detectors
Technical conditions TU BY 07513211.001-95
Liquid temperature indicator detectors (ДУТЖ) are designed for working in electric circuit of tem-perature indicator, which are installed in engines with water cooling of cars, tractors and special equipment.
Detectors are applied in direct-wire circuit of electric equipment with nominal voltage 12 or 24 V of direct current and completed with suitable magnetoelectric type of indicator.
Type of detector – thermistor.
The kind of climatic modification – O1 by GOST 15150. Thus bottom working environment temperature value during maintenance is minus 50˚С, and for run-down state is minus 60°С.
Operating mode is continued and nominal S1 by GОСТ 3940.
Data recording in technical documentation and in order example:
“Liquid temperature indicator detector ДУТЖ 02М TU BY 07513211.001-95”
Technical characteristics of the ДУТЖ are specified in table 1.
Designating |
Liquid temperature indicator detector |
Thread on body |
Method of attachment |
Readout detector range , °С / (Nominal voltage, V) |
Detector resistance, Ом |
Temperature of wear, °С / Temperature of retrace, °С |
Current – 0,1 А |
||||||
АДЮИ.405213.001 |
ДУТЖ |
Conical K 3/8'' ГОСТ 6111-58 |
Dowel 01-6,3-00 ОСТ 37.003.032-88 |
40-120 / (12 or 24) |
530-51 |
––– |
АДЮИ.405213.001-01 |
ДУТЖ-01 |
Screw В.М4-6gх8.58.016 ГОСТ 17473-80 |
||||
АДЮИ.405213.001-02 |
ДУТЖ-02 |
Dowel 01-6,3-00 ОСТ 37.003.032-88 |
40-120 / (12) |
267-20 |
||
АДЮИ.405213.001-03 |
ДУТЖ-05 |
Screw М4-6gх8.58.016 ГОСТ 17473-80 |
/ (24) |
|
||
АДЮИ.453842.003 |
ДУТЖ-02М |
Dowel pad 501202 ОСТ 37.003.032-88 |
40-120 / (12) |
267-20 |
||
АДЮИ.453842.003-01 |
ДУТЖ-06М |
Metrical М16х1,5-6g |
||||
АДЮИ.453842.001 |
ДУТЖ-03 |
Conical K 3/8'' ГОСТ 6111-58 |
Bayonet socket (connector analog DIN-72585-1
|
40-120 / (12 or 24) |
530-51 |
+105+4 -3 / 92 min |
АДЮИ.453842.001-01 |
ДУТЖ-04 |
+96+4 -3 / 83 min |
Detectors ДУТЖ-03 и ДУТЖ-04 are combined and produce signal as for temperature indicator so in control lamp at emergency temperature increasing. Temperature of actuating and retrace of the alarm signaling contact in detector must match values from table 2.
Detector type |
Temperature of actuating (at temperature increase), °С |
Temperature of retrace (at temperature decrease), °С |
|
Bottom value |
Upper value |
Bottom value |
|
ДУТЖ-03 |
102 |
109 |
92 |
ДУТЖ-04 |
93 |
100 |
83 |